产品中心
PASR-9000A is suitable for monitoring emergency stop switches and safety doors.
所属分类:
PASR-9000 Series
The PASR series safety modules are primarily used between safety protection components of machinery and equipment—such as safety door switches, emergency stop switches, and safety light curtains—and start/stop control components—such as relays and hydraulic solenoid valves—to verify the machine’s safety inputs, including whether the safety door is fully closed, whether the safety light curtain is obstructed, and whether the safety valve spool is jammed.
输入设备:
Emergency Stop Button/Safety Door
供电电压:
24V DC
输出触点数:
3NO+1NC
复位方式:
Automatic / Manual Reset
触点切换容量:
5A

- 产品对比
去对比
Basic Parameters |
|
| Number of channels | Dual-channel input |
Switching capacity |
|
| Three-way normally open contacts | AC 15:5A/250VAC |
DC13:6A/DC24V |
|
| Rated heating current Ith | 5A |
| Insurance Level | 6A fast or 4A slow |
| Usage Category | AC-15, DC-13 |
Time |
|
| Dual-channel input time | No limit |
| Safe Output Duration at Rated Voltage | Manual start: 35 ms |
| Safe Disconnection Time at Rated Voltage | 10ms |
| Contact Materials and Their Structures | AgSnO + 0.2 µm Au, forced-break contact |
| Contact resistance | ≤100 mΩ |
| Mechanical life | 10 million times |
| Operating frequency | 6 times per minute |
| Status Display | Three green LEDs |
| Start Button Monitoring | Manual start/Automatic start |
| Rated Insulation Voltage | 300 V (Pollution Degree 2 in accordance with IEC 60947-5-1) |
| Rated impulse withstand voltage | 2500 V (Category 2 overvoltage as defined in IEC 60947-5-1) |
| Applicable | Emergency stop switch, safety door |
Input parameters |
|
| Input | Dual channel |
| Input current | ≤10mA |
| Wire resistance | ≤15Ω |
Output data |
|
| Output signal | Semiconductor Output |
| Output channel | Three normally open outputs (13-14, 23-24, 33-34) |
Normally Closed Output (41–42) |
|
Power supply |
|
| Power supply voltage | 24VDC |
| Voltage range | 85%~110% |
| Module power consumption | ≤3W (24VDC) |
Size |
|
| Height | 114.5mm |
| Width | 99mm |
| Thickness | 22.5mm |
Housing |
|
| Materials | Flame-retardant ABS |
| Protection Level | IP20 |
| Flame-retardant rating | UL94/V0 |
| Color | Gray + Yellow |
EMC data |
|
| Electrical Fast Transient/Burst Immunity | Standards: IEC 61326-1; Class A |
| Surge (Impulse) Immunity | Standards: IEC 61326-1; Class B |
| Radio-frequency electromagnetic field radiation immunity | Standards: IEC 61326-1; Compliance with Essential Requirements |
| Electrostatic Discharge Immunity | Standards: IEC 61326-1; Class A |
| Immunity to Conducted Disturbances Induced by Radio-Frequency Fields | Standards: IEC 61326-1; Compliance with Essential Requirements |
| Low-Frequency Common-Mode Conduction | Standards: IEC 61326-1; Compliance with Essential Requirements |
| Meets the standard | BS EN 62061:2015, ISO 13849-1:2015, ISO 13849-2:2012, IEC EN 60204-1, ISO 13849-1 |
| Safety Integrity Level (SIL) | EN 954-1, Maximum Safety Integrity Level 4 |
| Performance Level (PL) | ISO 13849-1:2015, PL e |
Operating Environment |
|
| Continuous operating temperature | -20℃~+60℃ |
| Storage temperature | '-40℃ to +85℃ |
| Relative humidity | <90% RH (no condensation) |
| Environmental Requirements | The surrounding environment shall be free from severe vibration, impact, and electromagnetic interference such as high currents and sparks. The air shall not contain any corrosive media that can attack chromium, nickel, or silver plating, nor shall it contain flammable or explosive substances. |
Connection Parameters |
|
| Wire cross-sectional area range | 0.5~2.5 mm² |
| Minimum Wire Cross-Sectional Area AWG | 12 |
| Maximum Conductor Cross-Sectional Area AWG | 24 |
| Wire stripping length | 8mm |
| Thread | M3 |
| Connection method | Screw connection |
| Minimum Tightening Torque | 0.5 Nm |
| Maximum Tightening Torque | 0.6 Nm |
Install |
|
| Installation Method | DIN 35 mm rail mounting |
文件名称
文件大小
所属分类
上传时间
预览下载
207.0KB
Safety relay
2023-09-04
文件名称
所属分类
下载