  • 信号隔离器(2).png
  • 5f6faf89-ec5f-4093-bef3-c09f9f770f1b (1)(12).jpg
  • 85332a42-8f78-4083-b6a6-0ac9f3eb0c97(26).png
  • 86d7e03c-bb98-488c-a1b9-7beb79b1d0eb(25).jpg

PF-10 Weighing transmitter

Picture Name

Classification:

PF series

● Power supply indication; ● Input/output/power isolation; ● Two 35002 sensors can be carried at the same time.

Product Details Technical parameters Download

Close
  • 产品对比
Total X Clear all

Contrast

General
Number of channels 1input/1output
Output accuracy(20°C) 0.1%F.S.
Temperature drift 50ppm/K
Response time <0.05s (0~90%) (TYP)
Dielectric strength 1500VAC/1min,2mA
Insulation resistance ≥100MΩ;500VDC
Electromagnetic compatibility compliant with GB/T18268 (IEC61326-1)
Weight About 90g
Input data
Input signal 0-100mV
Input impedance Voltage type≥100KΩ
Frequency signal 5V,10V,12V
Frequency ≤110KHz
Output data
Output signal -10V~+10V;0~20mA
Output impedance Current type ≤ 500 Ω; Voltage type ≥ 10K Ω
Power supply
Supply voltage(Ue) 24VDC±10%
Power protection Reverse protection of power supply
Power consumption <1W
Power supply mode Independent power supply
Power connecting mode Terminal power supply;Base power supply
Overall dimension
height 121mm
width 113mm
Thickness 13.3mm
Housing
Material ABSflame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour white+grey
EMC data
Electrical fast transient/burst immunity compliant with:IEC 61326-1;A-leve
Surge immunity compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity compliant with:IEC 61326-1
Electrostatic discharge immunity compliant with:IEC 61326-1;A-leve
mmunity to conducted disturbances, induced by radio-frequency fields compliant with:IEC 61326-1
Immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz compliant with:IEC 61326-1
Operating conditions
Ambient temperature -20ºC~+60ºC
Storage temperature -40ºC~+80ºC
Relative humidity <90% RH (no condensate)
Environmental requirements The air should not contain any medium corrupting the coat of chrome,nickel and silver.Moreover,violent quiver and impact or any cause of electromagnetic induction (such as big current or spark,etc.)must be avoided when using
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min 12
Conductor cross section AWG max 24
Stripping length 8mm
Screw thread M3
Connection method Screw connection
Tightening torque min 0.5 Nm
Tightening torque max 0.6 Nm
Installation
Installation method DIN35mm

File Name

File Size

Classification

Upload time

Download

227.0KB

Weighing transmitter

2023-09-04

< 1 >

File Name

Classification

Download