Products
PF-40 Precision weighing transmitter (isolation and anti-interference type)
Classification:
PF series
● Accuracy up to 3/10000; ● Up to 4350Q sensors; ● 35mm DIN rail mounted, plug-in terminal; ● Optional Bluetooth communication module, using mobile Output interface phone calibration standards; ● RS485 output, support ModBus RTU protocol; ● The input/output/power channels are isolated, Good anti-jamming effect.
Product Details
Technical parameters
Download

Close
- 产品对比
Contrast
| General | |
| Number of channels | 1input/1output |
| Output accuracy(20°C) | 0.1% F.S. (customizable to 0.03% F.S.) |
| Temperature drift | 50ppm/K |
| Response time | <0.05s (0~90%) (TYP) |
| Dielectric strength | 1500VAC/1min,2mA |
| Insulation resistance | ≥100MΩ;500VDC |
| Electromagnetic compatibility | compliant with GB/T18268 (IEC61326-1) |
| Weight | About 160g |
| Input data | |
| Input signal | 1mV/V;2mV/V;3mV/V |
| Input range | ±35mV |
| Output data | |
| Output signal | RS485 |
| Power supply | |
| Supply voltage(Ue) | 24VDC±10% |
| Power protection | Reverse protection of power supply |
| Power consumption | 3W |
| Power supply mode | Independent power supply |
| Power connecting mode | Terminal power supply |
| Overall dimension | |
| height | 114.5mm |
| width | 99mm |
| Thickness | 22.5mm |
| Housing | |
| Material | ABSflame retardant |
| Degree of protection | IP20 |
| Flammability rating | UL94/V0 |
| Colour | white+grey |
| EMC data | |
| Electrical fast transient/burst immunity | compliant with:IEC 61326-1;A-leve |
| Surge immunity | compliant with:IEC 61326-1;B-leve |
| Radiated,radio-frequency,electromagnetic field immunity | compliant with:IEC 61326-1 |
| Electrostatic discharge immunity | compliant with:IEC 61326-1;A-leve |
| mmunity to conducted disturbances, induced by radio-frequency fields | compliant with:IEC 61326-1 |
| Immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz | compliant with:IEC 61326-1 |
| Operating conditions | |
| Ambient temperature | -20ºC~+60ºC |
| Storage temperature | -40ºC~+80ºC |
| Relative humidity | <90% RH (no condensate) |
| Environmental requirements | The air should not contain any medium corrupting the coat of chrome,nickel and silver.Moreover,violent quiver and impact or any cause of electromagnetic induction (such as big current or spark,etc.)must be avoided when using |
| Connection data | |
| Conductor cross section solid range | 0.5~2.5mm² |
| Conductor cross section AWG min | 12 |
| Conductor cross section AWG max | 24 |
| Stripping length | 8mm |
| Screw thread | M3 |
| Connection method | Screw connection |
| Tightening torque min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
| Installation | |
| Installation method | DIN35mm |
File Name
File Size
Classification
Upload time
Download
232.1KB
Weighing transmitter
2023-09-04
File Name
Classification
Download
Weighing transmitter