PC-22 Frequency isolation transmitter

Picture Name

Classification:

PC series

This product is a frequency isolation transmitter. The measured signal is isolated through high-precision isolation devices, and the output is standard signals such as linear 0-5V, 0-10V, 0-20mA, 4-20mA, etc. Widely used in industries such as power supply equipment, power grid monitoring, industrial control monitoring systems, and railway signal systems.

Number of channels:

Input:

45-55Hz,0-2KHz,0-10KHz,0-50Hz,0-65Hz,User defined

Output:

User defined,0~5V,0~10V,0~20mA,4~20mA

Power supply mode:

用户自定义,220Vac,220Vdc,12Vdc,24Vdc

Product Details Technical parameters Download

Close
  • 产品对比
Total X Clear all

Contrast

General
Output accuracy (20 ° C) 0.5
Response time ≤300ms
Insulation strength 1500VAC/1min,2mA
Insulation resistance Above 100MΩ at 500VDC
Electromagnetic compatibility Compliant with GB/T18268 (IEC61326-1)
Weight About 150g
Auxiliary power supply ﹢12Vdc、﹢15Vdc、﹢24Vdc、220Vac/dc
Load capacity Voltage output ≥ 2KΩ, current output ≤ 250Ω
Static power consumption ≤0.5W
Rated power consumption ≤1.5W
Isolation and withstand voltage DC2500V
Temperature coefficient ≤200ppm/℃
Lightning surge Power supply 2000V, input2000V,output 500V
Input data
Input signal 0-50Hz,0-65Hz,45-55Hz,0-2kHz,0-10kHz
Output data
Output signal 0~5V,0~10V,0~20mA,4~20mA(optional)
Overall dimension
Depth 110mm
Height 82mm
Width 28mm
Housing
Material ABS flame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour Grey
EMC data
Electrical fast transient/burst immunity Compliant with:IEC 61326-1;A-leve
Surge (impact) immunity Compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity Compliant with:IEC 61326-1;conform to basic requirements
Electrostatic discharge immunity Compliant with:IEC 61326-1;A-leve
Immunity to conducted disturbances, induced by radio-frequency fields Compliant with:IEC 61326-1;conform to basic requirements
Low frequency common mode conduction Compliant with:IEC 61326-1;conform to basic requirements
Operating conditions
Operating temperature ﹣10℃~﹢60℃
Storage temperature ﹣20℃~+70℃/less than 70% relative humidity (non condensing state)
Relative humidity < 90% RH(no condensate)
Environmental requirements There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min 12
Conductor cross section AWG max 24
Stripping length 8mm
Screw thread M3
Connection method Screw connection
Tightening torque min. 0.5 Nm
Tightening torque max. 0.6 Nm
Installation