This product is a frequency-isolated transmitter. It employs high-precision isolation components to electrically isolate the input signal, with output signals in standard ranges such as 0–5 V, 0–10 V, 0–20 mA, and 4–20 mA. It is widely used in power equipment, grid monitoring, industrial control monitoring systems, railway signaling systems, and other industries.

0-50 Hz,0-65 Hz,45-55 Hz,0-2 kHz,0-10 kHz,User-defined

0~5V,0~10V,4~20mA,0~20mA,User-defined

12Vdc,15 Vdc,24 Vdc,220 Vdc,User-defined,220Vac

img
产品详情 技术参数 下载

Close
  • 产品对比
Total X Clear all

去对比

Basic Parameters
Output accuracy (20°C) Class 0.5
Response time ≤300ms
Dielectric strength 1500V AC/1min, 2mA
Insulation resistance Greater than 100 MΩ at 500 VDC
Electromagnetic Compatibility Complies with GB/T 18268 (IEC 61326-1)
Weight About 150 grams
Auxiliary power supply +12 Vdc, +15 Vdc, +24 Vdc, +220 Vac/dc
Load capacity Voltage output ≥ 2 kΩ, current output ≤ 250 Ω
Static Power Consumption ≤0.5W
Rated Power Consumption 1.5W
Withstand Voltage Isolation DC2500V
Temperature coefficient ≤200 ppm/°C
Lightning Surge 2000 V at the power supply terminal, 2000 V at the input terminal, and 500 V at the output terminal.
Input data
Input signal 0–50 Hz, 0–65 Hz, 45–55 Hz, 0–2 kHz, 0–10 kHz
Output data
Output signal 0~5V, 0~10V, 0~20mA, 4~20mA
Size
Depth 110mm
Height 82mm
Width 28mm
Housing
Materials Flame-retardant ABS
Protection Level IP20
Flame-retardant rating UL94/V0
Color Gray
EMC data
Electrical Fast Transient/Burst Immunity Standards: IEC 61326-1; Class A
Surge (Impulse) Immunity Standards: IEC 61326-1; Class B
Radio-frequency electromagnetic field radiation immunity Standards: IEC 61326-1; Compliance with Essential Requirements
Electrostatic Discharge Immunity Standards: IEC 61326-1; Class A
Immunity to Conducted Disturbances Induced by Radio-Frequency Fields Standards: IEC 61326-1; Compliance with Essential Requirements
Low-Frequency Common-Mode Conduction Standards: IEC 61326-1; Compliance with Essential Requirements
Operating Environment
Operating temperature -10~60℃
Storage temperature -20°C to +70°C / Less than 70% relative humidity (non-condensing)
Relative humidity <90% RH (no condensation)
Environmental Requirements The surrounding environment shall be free from severe vibration, impact, and electromagnetic interference such as high currents and sparks. The air shall not contain any corrosive media that can attack chromium, nickel, or silver plating, nor shall it contain flammable or explosive substances.
Connection Parameters
Wire cross-sectional area range 0.5~2.5 mm²
Minimum Wire Cross-Sectional Area AWG 12
Maximum Conductor Cross-Sectional Area AWG 24
Wire stripping length 8mm
Thread M3
Connection method Screw connection
Minimum Tightening Torque 0.5 Nm
Maximum Tightening Torque 0.6 Nm
Install
Installation Method DIN 35 mm rail mounting