产品中心
PASR-9000BS is suitable for monitoring security carpets.
所属分类:
PASR-9000 Series
The PASR-9000BS is a safety relay designed for two- or four-wire safety carpet inputs, featuring two NO (normally open) safety output contacts, one NC (normally closed) auxiliary output contact, and one semiconductor auxiliary output. It supports both manual and automatic reset, as well as reset-button monitoring.
输入设备:
Two-/Four-Wire Safety Mat
供电电压:
24V DC/AC
输出触点数:
2NO+1NC
复位方式:
Automatic / Manual Reset
触点切换容量:
5A
产品详情
技术参数
下载

Close
- 产品对比
去对比
| Basic Parameters | |
| Contact material | AgSnO2 + 0.2 μm Au |
| Contact Type | Forced orientation |
| Contact Fuse Protection | 10A gL/gG, NEOZED (normally open contact) |
| 6A gL/gG, NEOZED (normally closed contact) | |
| Make-up buffer time | Automatic reset: ≤ 300 ms; Manual reset: ≤ 150 ms |
| Release buffer time | Emergency stop operation: ≤ 30 ms; Power failure: ≤ 100 ms |
| Recovery time | Emergency stop operation: ≤ 30 ms; Power failure: ≤ 100 ms |
| Rated Insulation Voltage | 250V AC |
| Rated Impulse Voltage | 4000 V (1.2/50 μs) |
| Applicable | Safety carpet |
| Input parameters | |
| Input | Two-/Four-Wire Safety Carpet (Termination Resistance: 1.0 kΩ ~ 10 kΩ) |
| Input current | ≤ 10 mA (24 V DC power supply) |
| Wire resistance | ≤15Ω |
| Power supply | |
| Power supply voltage | 24VDC/AC |
| Current loss | ≤ 120 mA (24 V DC); ≤ 300 mA (24 V AC) |
| Operating Environment | |
| Operating temperature | -20°C to +60°C |
| Storage temperature | -40°C to +85°C |
| Relative humidity | 10%~90% |
| Size | |
| Height | 114.5mm |
| Width | 99mm |
| Thickness | 22.5mm |