产品中心
DRG-2500-GJB CAN Isolated Safety Barrier, 100% Made in China
所属分类:
DRG Series
100% domestically produced safety barrier
The DRG-2500-GJB CAN (half-duplex) isolated safety barrier enables bidirectional communication of CAN (half-duplex) digital signals between hazardous and non-hazardous areas and provides power to field instruments. This product requires an independent power supply and features complete electrical isolation among the power supply, input, and output circuits. All internal electronic components are domestically manufactured, achieving a 100% localization rate.
通道数:
One in, one out
输入:
配电:
输出:
供电方式:
电源连接方式 :

- 产品对比
去对比
Basic Parameters |
|
| Number of channels | 1 in, 1 out |
| Dielectric strength | 1500 VAC for intrinsically safe terminals vs. non-intrinsically safe terminals; 1000 VAC for non-intrinsically safe terminals vs. non-intrinsically safe terminals. |
| Output precision | 0.1% F.S |
| Transmission latency | ≤10uS |
| Signal transmission rate | <250 Kbps |
| Temperature drift | 0.01% F.S/C |
| Transmission control method | Half-duplex |
| Power distribution for field instruments | 5V/100mA, 6V/100mA, 8V/50mA, 9V/50mA, 12A/50mA |
| Distribution Voltage Error | ±10% |
| Insulation resistance | Non-intrinsically safe terminal–intrinsically safe terminal ≥ 100 MΩ; power supply–non-intrinsically safe terminal ≥ 100 MΩ. |
| Electromagnetic Compatibility | Complies with IEC 61326-1 (GB/T 18268) and IEC 61326-3-1. |
| Explosion-proof marking | [Ex ia Ga]ⅡC |
| Weight | Approximately 150g |
| Connected field devices | Installed in a safe location, it can be connected to intrinsically safe instruments in Zone 0 where hazardous gases of Classes IIA, IIB, and IIC are present, and is equipped with a CAN (half-duplex) communication interface. |
| Applicable Locations | Zone 0, Zone 1, Zone 2; IIA, IIB, IIC hazardous areas |
Switch Settings |
|
| Power distribution | K1 K2 K3 K4 |
| 12V/50mA | OFF OFF OFF OFF |
| 9V/50mA | ON OFF OFF OFF |
| 8V/50mA | ON ON OFF OFF |
| 6V/100mA | ON ON ON OFF |
| 5V/100mA | ON ON ON ON |
Input data |
|
| Input signal range | CAN digital signal (half-duplex) |
Output data |
|
| Output signal range | CAN digital signal (half-duplex) |
Power supply |
|
| Power Supply | 20~35V DC |
| Power Protection | Reverse Power Protection |
| Power consumption | ≤140 mA (when powered by 24 V, with power distribution at 5 V/100 mA or 6 V/100 nA) |
| Power Supply Method | Independent power supply |
| Power Connection Method | Base power supply; terminal power supply |
Size |
|
| Centralized power supply | |
| Depth | 120.8mm |
| Height | 113mm |
| Width | 18.3mm |
| Independent power supply | |
| Depth | 110mm |
| Height | 108mm |
| Width | 18.3mm |
Housing |
|
| Materials | PC+ABS flame retardant |
| Protection Level | IP20 |
| Flame-retardant rating | UL94/V0 |
| Color | White + Gray |
EMC data |
|
| Electrical Fast Transient/Burst Immunity | Standards: IEC 61326-1; Class A |
| Surge (Impulse) Immunity | Standards: IEC 61326-1; Class B |
| Radio-frequency electromagnetic field radiation immunity | Standards: IEC 61326-1; Compliance with Essential Requirements |
| Electrostatic Discharge Immunity | Standards: IEC 61326-1; Class A |
| Immunity to Conducted Disturbances Induced by Radio-Frequency Fields | Standards: IEC 61326-1; Compliance with Essential Requirements |
| Low-Frequency Common-Mode Conduction | Standards: IEC 61326-1; Compliance with Essential Requirements |
Operating Environment |
|
| Continuous operating temperature | -20℃~+60℃ |
| Storage temperature | -40℃~+80℃ |
| Relative humidity | 10%~90% |
| Environmental Requirements | The surrounding environment shall be free from severe vibration, impact, and electromagnetic interference such as high currents and sparks. The air shall not contain any corrosive media that can attack chromium, nickel, or silver plating, nor shall it contain flammable or explosive substances. |
Connection Parameters |
|
| Wire cross-sectional area range | 0.5~2.5 mm² |
| Minimum Wire Cross-Sectional Area AWG | 24 |
| Maximum Conductor Cross-Sectional Area AWG | 12 |
| Wire stripping length | 8mm |
| Thread | M3 |
| Connection method | Screw connection |
| Minimum Tightening Torque | 0.5 Nm |
| Maximum Tightening Torque | 0.6 Nm |
Install |
|
| Installation Method | DIN 35 mm rail mounting |
| External dimensions | |||
| Base-centralized power supply type | Terminal-powered | ||
![]() |
![]() |
||
| Installation Method | |||
![]() |
![]() |
![]() |
![]() |
Basic Parameters |
|
| Number of channels | 1 in, 1 out |
| Dielectric strength | 1500 VAC for intrinsically safe terminals vs. non-intrinsically safe terminals; 1000 VAC for non-intrinsically safe terminals vs. non-intrinsically safe terminals. |
| Output precision | 0.1% F.S |
| Transmission latency | ≤10uS |
| Signal transmission rate | <250 Kbps |
| Temperature drift | 0.01% F.S/C |
| Transmission control method | Half-duplex |
| Power distribution for field instruments | 5V/100mA, 6V/100mA, 8V/50mA, 9V/50mA, 12A/50mA |
| Distribution Voltage Error | ±10% |
| Insulation resistance | Non-intrinsically safe terminal–intrinsically safe terminal ≥ 100 MΩ; power supply–non-intrinsically safe terminal ≥ 100 MΩ. |
| Electromagnetic Compatibility | Complies with IEC 61326-1 (GB/T 18268) and IEC 61326-3-1. |
| Explosion-proof marking | [Ex ia Ga]ⅡC |
| Weight | Approximately 150g |
| Connected field devices | Installed in a safe location, it can be connected to intrinsically safe instruments in Zone 0 where hazardous gases of Classes IIA, IIB, and IIC are present, and is equipped with a CAN (half-duplex) communication interface. |
| Applicable Locations | Zone 0, Zone 1, Zone 2; IIA, IIB, IIC hazardous areas |
Switch Settings |
|
| Power distribution | K1 K2 K3 K4 |
| 12V/50mA | OFF OFF OFF OFF |
| 9V/50mA | ON OFF OFF OFF |
| 8V/50mA | ON ON OFF OFF |
| 6V/100mA | ON ON ON OFF |
| 5V/100mA | ON ON ON ON |
Input data |
|
| Input signal range | CAN digital signal (half-duplex) |
Output data |
|
| Output signal range | CAN digital signal (half-duplex) |
Power supply |
|
| Power Supply | 20~35V DC |
| Power Protection | Reverse Power Protection |
| Power consumption | ≤140 mA (when powered by 24 V, with power distribution at 5 V/100 mA or 6 V/100 nA) |
| Power Supply Method | Independent power supply |
| Power Connection Method | Base power supply; terminal power supply |
Size |
|
| Centralized power supply | |
| Depth | 120.8mm |
| Height | 113mm |
| Width | 18.3mm |
| Independent power supply | |
| Depth | 110mm |
| Height | 108mm |
| Width | 18.3mm |
Housing |
|
| Materials | PC+ABS flame retardant |
| Protection Level | IP20 |
| Flame-retardant rating | UL94/V0 |
| Color | White + Gray |
EMC data |
|
| Electrical Fast Transient/Burst Immunity | Standards: IEC 61326-1; Class A |
| Surge (Impulse) Immunity | Standards: IEC 61326-1; Class B |
| Radio-frequency electromagnetic field radiation immunity | Standards: IEC 61326-1; Compliance with Essential Requirements |
| Electrostatic Discharge Immunity | Standards: IEC 61326-1; Class A |
| Immunity to Conducted Disturbances Induced by Radio-Frequency Fields | Standards: IEC 61326-1; Compliance with Essential Requirements |
| Low-Frequency Common-Mode Conduction | Standards: IEC 61326-1; Compliance with Essential Requirements |
Operating Environment |
|
| Continuous operating temperature | -20℃~+60℃ |
| Storage temperature | -40℃~+80℃ |
| Relative humidity | 10%~90% |
| Environmental Requirements | The surrounding environment shall be free from severe vibration, impact, and electromagnetic interference such as high currents and sparks. The air shall not contain any corrosive media that can attack chromium, nickel, or silver plating, nor shall it contain flammable or explosive substances. |
Connection Parameters |
|
| Wire cross-sectional area range | 0.5~2.5 mm² |
| Minimum Wire Cross-Sectional Area AWG | 24 |
| Maximum Conductor Cross-Sectional Area AWG | 12 |
| Wire stripping length | 8mm |
| Thread | M3 |
| Connection method | Screw connection |
| Minimum Tightening Torque | 0.5 Nm |
| Maximum Tightening Torque | 0.6 Nm |
Install |
|
| Installation Method | DIN 35 mm rail mounting |
| External dimensions | |||
| Base-centralized power supply type | Terminal-powered | ||
![]() |
![]() |
||
| Installation Method | |||
![]() |
![]() |
![]() |
![]() |
文件名称
文件大小
所属分类
上传时间
预览下载
208.8KB
Signal isolator
2023-09-19
144.4KB
Signal isolator
2023-09-19
450.8KB
Qualifications
2024-05-20
文件名称
所属分类
下载