产品中心

+
  • PASR-9000A侧.jpg
  • PASR-9000A正.jpg
  • 3(1).png

PASR-9000-AB is suitable for emergency stop switches and safety doors.

img

所属分类:

PASR-9000 Series

The PASR-9000-AB is a safety relay designed for emergency stop buttons and safety door interlock switches, featuring two NO (normally open) safety output contacts and two NC (normally closed) auxiliary output contacts. It supports single- or dual-channel operation, with manual or automatic reset, and includes inter-channel short-circuit monitoring.

输入设备:

Emergency Stop Button/Safety Door

供电电压:

24V DC

输出触点数:

2NO+2NC

复位方式:

Automatic / Manual Reset

触点切换容量:

5A

img
产品详情 技术参数 下载

Close
  • 产品对比
Total X Clear all

去对比

Basic Parameters
Number of channels Dual-channel input
Switching capacity
Rated heating current Ith 5A
Insurance Level 6A fast or 4A slow
Usage Category AC-15, DC-13
Time
Dual-channel input time No limit
Safe Output Duration at Rated Voltage Manual start: 35 ms
Safe Disconnection Time at Rated Voltage 10ms
Contact Materials and Their Structures AgSnO + 0.2 µm Au, forced-break contact
Contact resistance ≤100 mΩ
Mechanical life 10 million times
Operating frequency 6 times per minute
Status Display A green LED
Start Button Monitoring Manual start/Automatic start
Rated Insulation Voltage 300 V (Pollution Degree 2 in accordance with IEC 60947-5-1)
Rated impulse withstand voltage 2500 V (Category 2 overvoltage as defined in IEC 60947-5-1)
Applicable Emergency stop switch, safety door
Input parameters
Input Dual channel
Input current ≤50mA
Wire resistance ≤15Ω
Output data
Output capacity 2NO+2NC
Output channel Two normally open outputs (13-14, 23-24)
Route 2 normally closed outputs (31-32, 41-42)
Power supply
Power supply voltage 24VDC
Voltage range 85%~110%
Current loss

≤ 90 mA (24 V DC)

Size
Height 114.5mm
Width 99mm
Thickness 22.5mm
Housing
Materials Flame-retardant ABS
Protection Level IP20
Flame-retardant rating UL94/V0
Color Gray + Yellow
EMC data
Electrical Fast Transient/Burst Immunity Standards: IEC 61326-1; Class A
Surge (Impulse) Immunity Standards: IEC 61326-1; Class B
Radio-frequency electromagnetic field radiation immunity Standards: IEC 61326-1; Compliance with Essential Requirements
Electrostatic Discharge Immunity Standards: IEC 61326-1; Class A
Immunity to Conducted Disturbances Induced by Radio-Frequency Fields Standards: IEC 61326-1; Compliance with Essential Requirements
Low-Frequency Common-Mode Conduction Standards: IEC 61326-1; Compliance with Essential Requirements
Meets the standard BS EN 62061:2015, ISO 13849-1:2015, ISO 13849-2:2012, IEC EN 60204-1, ISO 13849-1
Safety Integrity Level (SIL) EN 954-1, Maximum Safety Integrity Level 4
Performance Level (PL) ISO 13849-1:2015, PL e
Operating Environment
Continuous operating temperature -20℃~+60℃
Storage temperature '-40℃ to +85℃
Relative humidity <90% RH (no condensation)
Environmental Requirements The surrounding environment shall be free from severe vibration, impact, and electromagnetic interference such as high currents and sparks. The air shall not contain any corrosive media that can attack chromium, nickel, or silver platings, nor shall it contain flammable or explosive substances.
Connection Parameters
Wire cross-sectional area range 0.5~2.5 mm²
Minimum Wire Cross-Sectional Area AWG 12
Maximum Conductor Cross-Sectional Area AWG 24
Wire stripping length 8mm
Thread M3
Connection method Screw connection
Minimum Tightening Torque 0.5 Nm
Maximum Tightening Torque 0.6 Nm
Install
Installation Method DIN 35 mm rail mounting