» Power indicator;
» Easy connectivity, low power consumption, and long service life;
» Complete isolation between input, output, power supply, and channels;
» Centralized power supply via the base, with hot-swappable support;
» Compact form factor, with a thickness of only 18.3 mm;
» DIN rail mounting, with plug-in terminals.
DG-113 Signal Distributor, Compatible with Two-, Three-, and Four-Wire Systems (One Input, Three Outputs)
» Power indicator;
» Easy connectivity, low power consumption, and long service life;
» Complete isolation between input, output, power supply, and channels;
» Centralized power supply via the base, with hot-swappable support;
» Compact form factor, with a thickness of only 18.3 mm;
» DIN rail mounting, with plug-in terminals.
×
● DC signal isolators (mV, V, mA)
● DC isolators isolate and convert DC current and voltage signals from industrial field environments into standard signals, thereby mitigating industrial signal interference. They feature current indication, surge protection, RS485 communication, and optional configuration settings.
DA-11 DC Signal Isolator (mV, V, mA)
● DC signal isolators (mV, V, mA)
● DC isolators isolate and convert DC current and voltage signals from industrial field environments into standard signals, thereby mitigating industrial signal interference. They feature current indication, surge protection, RS485 communication, and optional configuration settings.
×
● Single-input, single-output AC transmitter
● Terminals support live plugging and unplugging; compact design
● Complete isolation among input, output, and power supply—three-port isolation
DA-12 Single-Channel AC Transmitter
● Single-input, single-output AC transmitter
● Terminals support live plugging and unplugging; compact design
● Complete isolation among input, output, and power supply—three-port isolation
×
● Single-input, single-output power distribution isolator; compatible with 2-, 3-, and 4-wire configurations.
● DC isolators isolate and convert DC current and voltage signals from industrial environments into standard signals, effectively mitigating signal interference. They feature current indication, surge protection, RS485 communication, and optional configuration settings.
DA-13 Signal Isolator (Universal for Two-, Three-, and Four-Wire Systems)
● Single-input, single-output power distribution isolator; compatible with 2-, 3-, and 4-wire configurations.
● DC isolators isolate and convert DC current and voltage signals from industrial environments into standard signals, effectively mitigating signal interference. They feature current indication, surge protection, RS485 communication, and optional configuration settings.
×
● Single-input, single-output thermoresistance signal isolator
● Features power supply and alarm indication; surge protection or RS485 communication can be added; input and output ranges are programmable. It isolates and converts field temperature signals such as PT100 into standard signals or thermoresistance signals.
DA-14 Thermal Resistance Isolation Transmitter
● Single-input, single-output thermoresistance signal isolator
● Features power supply and alarm indication; surge protection or RS485 communication can be added; input and output ranges are programmable. It isolates and converts field temperature signals such as PT100 into standard signals or thermoresistance signals.
×
● Input-to-output thermoresistance-to-thermoresistance signal isolator
● 24 V power supply; fully isolated three-port design—input, output, and power supply
● Includes power supply and alarm indicator
DA-14-T Thermoresistance Input/Thermoresistance Output Isolator
● Input-to-output thermoresistance-to-thermoresistance signal isolator
● 24 V power supply; fully isolated three-port design—input, output, and power supply
● Includes power supply and alarm indicator
×
● Single-input, single-output thermocouple signal isolator
● Equipped with power supply and alarm indication; surge protection or RS485 communication can be added; input and output ranges are programmable. It isolates and converts thermocouple temperature signals—such as K, B, S, and R types—into standard DC signals like 4–20 mA or 0–5 V, or back to thermocouple signals, thereby addressing signal interference, conversion, transmission, and matching in industrial environments.
DA-15 Thermocouple Isolation Transmitter
● Single-input, single-output thermocouple signal isolator
● Equipped with power supply and alarm indication; surge protection or RS485 communication can be added; input and output ranges are programmable. It isolates and converts thermocouple temperature signals—such as K, B, S, and R types—into standard DC signals like 4–20 mA or 0–5 V, or back to thermocouple signals, thereby addressing signal interference, conversion, transmission, and matching in industrial environments.
×
● Thermocouple-to-thermocouple signal conversion (one input, one output)
● 24 V power supply; fully isolated three-port design for input, output, and power.
DA-15-T Thermocouple Input/Thermocouple Output Isolator
● Thermocouple-to-thermocouple signal conversion (one input, one output)
● 24 V power supply; fully isolated three-port design for input, output, and power.
×
● Single-in, single-out potentiometer signal isolator
● 24 V power supply; fully isolated three-port design with input, output, and power supply
● Equipped with power and alarm indicators; optional surge protection or RS-485 interface
DA-16 Potentiometer Isolation Transmitter
● Single-in, single-out potentiometer signal isolator
● 24 V power supply; fully isolated three-port design with input, output, and power supply
● Equipped with power and alarm indicators; optional surge protection or RS-485 interface
×
● Single-input, single-output frequency-isolated transmitter
● 24 V power supply; fully isolated three-port design—input, output, and power supply
● Easy to connect, low power consumption, long service life.
DA-17 Frequency-to-Analog Transmitter
● Single-input, single-output frequency-isolated transmitter
● 24 V power supply; fully isolated three-port design—input, output, and power supply
● Easy to connect, low power consumption, long service life.
×
● One-in, one-out analog-to-frequency signal isolation transmitter
● 24 V power supply; fully isolated three-port design—input, output, and power supply
● Easy to connect, low power consumption, long service life. Can also be used for analog-to-frequency signal conversion.
DA-71 Analog-to-Frequency Isolated Transmitter
● One-in, one-out analog-to-frequency signal isolation transmitter
● 24 V power supply; fully isolated three-port design—input, output, and power supply
● Easy to connect, low power consumption, long service life. Can also be used for analog-to-frequency signal conversion.
×
● Input–output frequency-to-frequency isolated transmitter
● 24 V power supply; fully isolated three-port design with input, output, and power supply
● Centralized power supply via the base, supporting hot-swapping.
DA-18 Frequency-to-Frequency Isolating Transmitter
● Input–output frequency-to-frequency isolated transmitter
● 24 V power supply; fully isolated three-port design with input, output, and power supply
● Centralized power supply via the base, supporting hot-swapping.
×
● One-input, two-output DC signal isolator (mV, V, mA)
● This DC isolator isolates and converts DC current and voltage signals from industrial field environments into standard signals, effectively mitigating industrial signal interference. It features current indication, surge protection, RS485 communication, and optional configuration settings.
DR-112 DC Signal Distributor (One Input, Two Outputs)
● One-input, two-output DC signal isolator (mV, V, mA)
● This DC isolator isolates and converts DC current and voltage signals from industrial field environments into standard signals, effectively mitigating industrial signal interference. It features current indication, surge protection, RS485 communication, and optional configuration settings.
×
● 一入二出交流变送器
● 端子可带电插拔,结构紧凑,输入 、输出、电源,三端口全隔离。
DR-212 交流信号分配器(一入二出)
● 一入二出交流变送器
● 端子可带电插拔,结构紧凑,输入 、输出、电源,三端口全隔离。
×
● Single-input, dual-output power distribution isolator; compatible with 2-, 3-, and 4-wire configurations.
● DC isolators isolate and convert DC current and voltage signals from industrial environments into standard signals, effectively mitigating signal interference. They feature current indication, optional surge protection, RS485 communication, and configurable settings.
DR-312 Signal Distributor, Compatible with Two-, Three-, and Four-Wire Systems (One Input, Two Outputs)
● Single-input, dual-output power distribution isolator; compatible with 2-, 3-, and 4-wire configurations.
● DC isolators isolate and convert DC current and voltage signals from industrial environments into standard signals, effectively mitigating signal interference. They feature current indication, optional surge protection, RS485 communication, and configurable settings.
×
● Single-input, dual-output thermal resistance signal isolator
● Features power supply and alarm indication; surge protection or RS485 communication can be added; input and output ranges are programmable. It isolates and converts field temperature signals such as PT100 into standard signals or thermal resistance signals.
DR-412 Thermoresistance Signal Distributor (One Input, Two Outputs)
● Single-input, dual-output thermal resistance signal isolator
● Features power supply and alarm indication; surge protection or RS485 communication can be added; input and output ranges are programmable. It isolates and converts field temperature signals such as PT100 into standard signals or thermal resistance signals.
×
● 一入一出热电偶信号隔离器
● 带电源、报警指示,可加浪涌保护或RS485信号,输入输出量程可编程。将K、B、S、R等热电偶温度信号,隔离、转换为4-20mA、0-5V等直流标准信号或热电偶信号,解决工业现场信号干扰、转换、传输及匹配问题。
DR-512 热电偶信号分配器(一入二出)
● 一入一出热电偶信号隔离器
● 带电源、报警指示,可加浪涌保护或RS485信号,输入输出量程可编程。将K、B、S、R等热电偶温度信号,隔离、转换为4-20mA、0-5V等直流标准信号或热电偶信号,解决工业现场信号干扰、转换、传输及匹配问题。
×
● 一入二出热电阻信号隔离器
● 24V供电,输入 、输出、电源,三端口全隔离
● 一入二出 热电阻信号转热电阻信号。
DR-412-T 热电阻输入/热电阻输出隔离器 (一入二出)
● 一入二出热电阻信号隔离器
● 24V供电,输入 、输出、电源,三端口全隔离
● 一入二出 热电阻信号转热电阻信号。
×
● 一入二出 热电偶转热电偶信号隔离器
● 24V供电,输入 、输出、电源,三端口全隔离
● 解决工业现场信号干扰、转换、传输及匹配问题。
DR-512-T 热电偶输入/热电偶输出隔离器(一入二出)
● 一入二出 热电偶转热电偶信号隔离器
● 24V供电,输入 、输出、电源,三端口全隔离
● 解决工业现场信号干扰、转换、传输及匹配问题。
×
● Single-input, dual-output potentiometer signal isolator
● 24 V power supply; fully isolated three-port design with input, output, and power supply
● Equipped with power and alarm indicators; surge protection or RS485 interface available as options.
DR-612 Potentiometer Signal Isolator and Distributor (One Input, Two Outputs)
● Single-input, dual-output potentiometer signal isolator
● 24 V power supply; fully isolated three-port design with input, output, and power supply
● Equipped with power and alarm indicators; surge protection or RS485 interface available as options.