DRG-6001 Thermal Resistance Signal Alarm Setter
● Converts the signals from field-mounted 2-, 3-, or 4-wire resistance temperature detectors into standard 4–20 mA DC signals.
● Controls two relay alarm outputs to the isolation barrier based on user-defined measurement ranges, alarm setpoints, and alarm modes.
DRG-6001 Thermal Resistance Signal Alarm Setter
● Converts the signals from field-mounted 2-, 3-, or 4-wire resistance temperature detectors into standard 4–20 mA DC signals.
● Controls two relay alarm outputs to the isolation barrier based on user-defined measurement ranges, alarm setpoints, and alarm modes.
×
DRG-6002 Thermocouple/Millivolt Signal Alarm Setter
● The thermocouple/mV signal alarm setpoint device converts on-site thermocouple/mV signals into a standard 4 mA to 20 mA DC current signal and isolates this signal for transmission to the safe side.
● Based on user-defined range, alarm setpoints, alarm modes, and other parameters, it controls two relay alarm outputs connected to an isolation barrier.
DRG-6002 Thermocouple/Millivolt Signal Alarm Setter
● The thermocouple/mV signal alarm setpoint device converts on-site thermocouple/mV signals into a standard 4 mA to 20 mA DC current signal and isolates this signal for transmission to the safe side.
● Based on user-defined range, alarm setpoints, alarm modes, and other parameters, it controls two relay alarm outputs connected to an isolation barrier.
×
DRG-6003 Current/Voltage Signal Alarm Setter
● The current-input alarm setter provides an isolated power supply to field transmitters and receives the 4 mA to 20 mA DC (or 4 mA to 20 mA current-source) signal generated by the transmitter, which is then sampled by the AD converter and sent to the MCU.
● Based on user-configured parameters such as measurement range, alarm setpoints, and alarm modes, the MCU controls two relay alarm outputs and one 4 mA to 20 mA current-signal output.
DRG-6003 Current/Voltage Signal Alarm Setter
● The current-input alarm setter provides an isolated power supply to field transmitters and receives the 4 mA to 20 mA DC (or 4 mA to 20 mA current-source) signal generated by the transmitter, which is then sampled by the AD converter and sent to the MCU.
● Based on user-configured parameters such as measurement range, alarm setpoints, and alarm modes, the MCU controls two relay alarm outputs and one 4 mA to 20 mA current-signal output.
×
DRG-6004 Signal Selector (Two Inputs, One Output)
The PRG-6004 series analog signal transmitter is an isolator with two signal inputs and one signal output. It automatically compares the magnitudes of the two input signals to select one for output (with user-selectable high- or low-output mode), or it allows the user to manually select one input signal via a digital/on-off signal or level signal, before isolating and outputting the selected signal.
DRG-6004 Signal Selector (Two Inputs, One Output)
The PRG-6004 series analog signal transmitter is an isolator with two signal inputs and one signal output. It automatically compares the magnitudes of the two input signals to select one for output (with user-selectable high- or low-output mode), or it allows the user to manually select one input signal via a digital/on-off signal or level signal, before isolating and outputting the selected signal.