Products

×

DRG-6001 Thermal resistance signal alarm setter

● The thermal-resistance signal alarm setter converts the 2/3 wire thermal-resistance signal into the standard 4-20MADC signal, and controls the alarm output of two-channel relays according to the user-set range, alarm point, alarm mode and other parameters.
DRG-6001 Thermal resistance signal alarm setter

DRG-6001 Thermal resistance signal alarm setter

● The thermal-resistance signal alarm setter converts the 2/3 wire thermal-resistance signal into the standard 4-20MADC signal, and controls the alarm output of two-channel relays according to the user-set range, alarm point, alarm mode and other parameters.
×

DRG-6002 Thermocouple/millivolt signal alarm setter

The thermocouple/millivolt signal alarm setter converts the on-site thermocouple/millivolt signal into a standard 4mA~20mADC current signal for isolation and transmission to the safety side Control two relay alarm outputs to the isolation barrier based on user set range, alarm point, alarm mode and other parameters.
DRG-6002 Thermocouple/millivolt signal alarm setter

DRG-6002 Thermocouple/millivolt signal alarm setter

The thermocouple/millivolt signal alarm setter converts the on-site thermocouple/millivolt signal into a standard 4mA~20mADC current signal for isolation and transmission to the safety side Control two relay alarm outputs to the isolation barrier based on user set range, alarm point, alarm mode and other parameters.
×

DRG-6003 Current/voltage signal alarm setter

The current input alarm setter provides isolation power to the on-site transmitter and receives a 4mA~20mADC (or 4mA~20mA current source signal) generated by the transmitter, which is sampled by AD and sent to the MCU The MCU controls two relay alarm outputs and one 4mA~20mA current signal output based on user set range, alarm point, alarm mode and other parameters.
DRG-6003 Current/voltage signal alarm setter

DRG-6003 Current/voltage signal alarm setter

The current input alarm setter provides isolation power to the on-site transmitter and receives a 4mA~20mADC (or 4mA~20mA current source signal) generated by the transmitter, which is sampled by AD and sent to the MCU The MCU controls two relay alarm outputs and one 4mA~20mA current signal output based on user set range, alarm point, alarm mode and other parameters.
×

DRG-6004 Signal selector (two in one out)

The DRG-6004 series analog signal transmitter is a two channel signal input and one channel signal output isolator. The two signals are automatically compared in size to select one input signal (user selects high or low output), or one input signal is selected through switch signal/level signal control, and then the selected signal is isolated and output.
DRG-6004 Signal selector (two in one out)

DRG-6004 Signal selector (two in one out)

The DRG-6004 series analog signal transmitter is a two channel signal input and one channel signal output isolator. The two signals are automatically compared in size to select one input signal (user selects high or low output), or one input signal is selected through switch signal/level signal control, and then the selected signal is isolated and output.