产品中心
PRODUCTS
产品中心
×
PASR-8000-2AE DO signal (FGS/GDS system) 2AE
The PASR-8000-2AE is a safety relay control module designed for DO signal isolation and conversion in FGS/GDS systems. It features two normally de-energized safety contacts (ND/ETS) and can monitor the status of field loads. The internal circuitry incorporates fail-safe technology and triple redundancy, with an output contact rating of up to 5 A.
PASR-8000-2AE DO signal (FGS/GDS system) 2AE
The PASR-8000-2AE is a safety relay control module designed for DO signal isolation and conversion in FGS/GDS systems. It features two normally de-energized safety contacts (ND/ETS) and can monitor the status of field loads. The internal circuitry incorporates fail-safe technology and triple redundancy, with an output contact rating of up to 5 A.
×
PASR-8000-1A DO signal (SIS system) 1NO
The PASR-8000-1A is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally open (NO) contact and incorporates fail-safe circuitry, triple redundancy, and contact weld protection, meeting the requirements of IEC 61508 and achieving a Safety Integrity Level of SIL 3.
PASR-8000-1A DO signal (SIS system) 1NO
The PASR-8000-1A is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally open (NO) contact and incorporates fail-safe circuitry, triple redundancy, and contact weld protection, meeting the requirements of IEC 61508 and achieving a Safety Integrity Level of SIL 3.
×
PASR-8000-1B DO signal (SIS system) 1NC
The PASR-8000-1B is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally closed (NC) contact and incorporates fail-safe technology, dual redundancy, and contact welding protection in its internal circuitry. The module complies with IEC 61508 requirements and achieves a Safety Integrity Level of SIL 2.
PASR-8000-1B DO signal (SIS system) 1NC
The PASR-8000-1B is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally closed (NC) contact and incorporates fail-safe technology, dual redundancy, and contact welding protection in its internal circuitry. The module complies with IEC 61508 requirements and achieves a Safety Integrity Level of SIL 2.
×
PASR-8000-1AR DO signal (SIS system) 1 NO
The PASR-8000-1AR is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally open (NO) contact and includes provisioned terminals to facilitate rapid offline proof testing. The internal circuitry incorporates fail-safe technology, triple redundancy, and contact welding protection, meeting the requirements of IEC 61508 and achieving a Safety Integrity Level of SIL 3.
PASR-8000-1AR DO signal (SIS system) 1 NO
The PASR-8000-1AR is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally open (NO) contact and includes provisioned terminals to facilitate rapid offline proof testing. The internal circuitry incorporates fail-safe technology, triple redundancy, and contact welding protection, meeting the requirements of IEC 61508 and achieving a Safety Integrity Level of SIL 3.
×
PASR-8000-1AR1B DO signal (SIS system) 1 NO + 1 NC
The PASR-8000-1AR1B is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally open (NO) safety contact and one normally closed (NC) auxiliary contact, with provisioned terminals to facilitate rapid offline proof testing. The panel-mounted fuse holder is pre-equipped with a 5 A fuse for protection, enabling users to quickly replace any blown fuses. The internal circuitry incorporates fail-safe technology, triple redundancy, and contact welding protection, meeting the requirements of IEC 61508 and achieving a Safety Integrity Level of up to SIL 3.
PASR-8000-1AR1B DO signal (SIS system) 1 NO + 1 NC
The PASR-8000-1AR1B is a safety relay control module designed for DIO signal isolation and conversion in SIS systems. It features one normally open (NO) safety contact and one normally closed (NC) auxiliary contact, with provisioned terminals to facilitate rapid offline proof testing. The panel-mounted fuse holder is pre-equipped with a 5 A fuse for protection, enabling users to quickly replace any blown fuses. The internal circuitry incorporates fail-safe technology, triple redundancy, and contact welding protection, meeting the requirements of IEC 61508 and achieving a Safety Integrity Level of up to SIL 3.
×
PASR-8000-2A2B DO signal (SIS system) 2 NO + 2 NC
The PASR-8000-2A2B is a safety relay designed for emergency stop buttons, safety door interlock switches, and DIO signal inputs in SIS systems. It features two NO (normally open) safety output contacts and two NC (normally closed) auxiliary output contacts. The device supports single- or dual-channel operation, with manual or automatic reset, and includes inter-channel short-circuit monitoring.
PASR-8000-2A2B DO signal (SIS system) 2 NO + 2 NC
The PASR-8000-2A2B is a safety relay designed for emergency stop buttons, safety door interlock switches, and DIO signal inputs in SIS systems. It features two NO (normally open) safety output contacts and two NC (normally closed) auxiliary output contacts. The device supports single- or dual-channel operation, with manual or automatic reset, and includes inter-channel short-circuit monitoring.
×
PASR-8000-3A1B DO signal (SIS system) 3 NO + 1 NC
The PASR-8000-3A1B is a safety relay designed for emergency stop buttons, safety door interlock switches, and DIO signal inputs in SIS systems, featuring three NC (normally closed) auxiliary output contacts. It supports single- or dual-channel operation, with manual or automatic reset, and includes inter-channel short-circuit monitoring.
PASR-8000-3A1B DO signal (SIS system) 3 NO + 1 NC
The PASR-8000-3A1B is a safety relay designed for emergency stop buttons, safety door interlock switches, and DIO signal inputs in SIS systems, featuring three NC (normally closed) auxiliary output contacts. It supports single- or dual-channel operation, with manual or automatic reset, and includes inter-channel short-circuit monitoring.